Aptos Solar DNA-120-MF10-445W with EG4 FlexBOSS21
Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 6–13 panels work. The longest string reaches 592 V on the coldest morning, under the 600 V inverter limit. One EG4 FlexBOSS21 takes up to 4 strings of 11: 44 panels, 19.58 kWp DC, DC/AC ratio 1.22.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning41.1 V × (1 + -0.306%/°C × (−10 − 25)) = 45.50 V per panel.
- Vmp on the hottest afternoonCells reach 69.6 °C (40 °C air plus the NMOT rise), so Vmp drops from 33.82 V to 27.63 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string600 V inverter limit ÷ 45.50 V = 13 panels.
- Shortest string120 V MPPT minimum ÷ 27.63 V = 5 panels; start-up voltage needs 6.
- Strings per MPPTHot-day Isc 14.13 A per string, so the MPPT inputs take 2 + 2 + 1 string(s); expect about 1.2% current clipping at peak.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 6–12 panels per string (best 10) |
| Chicago, IL | −21 °C | 6–12 panels per string (best 10) |
| Denver, CO | −23.6 °C | 6–12 panels per string (best 10) |
| Atlanta, GA | −9.5 °C | 6–13 panels per string (best 11) |
| Dallas, TX | −7.1 °C | 6–13 panels per string (best 11) |
| Phoenix, AZ | 1.3 °C | 6–13 panels per string (best 11) |
| Miami, FL | 5.9 °C | 6–13 panels per string (best 12) |
Common system sizes
How Aptos Solar DNA-120-MF10-445W panels lay out on the EG4 FlexBOSS21 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| 1 inverter, fully loaded | 45 | 5 strings of 9 on 1 inverter | 20.02 kWp | 1.25 |
| 2 inverters, fully loaded | 90 | 10 strings of 9 on 2 inverters | 40.05 kWp | 1.25 |
| 4 inverters, fully loaded | 180 | 20 strings of 9 on 4 inverters | 80.10 kWp | 1.25 |