Canadian Solar HiKu6 CS6R-410MS with EG4 12000XP
Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 5–11 panels work. The longest string reaches 446 V on the coldest morning, under the 480 V inverter limit. One EG4 12000XP takes up to 4 strings of 10: 40 panels, 16.40 kWp DC, DC/AC ratio 1.37.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning37.2 V × (1 + -0.26%/°C × (−10 − 25)) = 40.59 V per panel.
- Vmp on the hottest afternoonCells reach 66.2 °C (40 °C air plus the NMOT rise), so Vmp drops from 31.2 V to 26.18 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string480 V inverter limit ÷ 40.59 V = 11 panels.
- Shortest string120 V MPPT minimum ÷ 26.18 V = 5 panels; start-up voltage needs 4.
- Strings per MPPTHot-day Isc 14.30 A per string, so the MPPT inputs take 2 + 2 string(s).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 5–11 panels per string (best 10) |
| Chicago, IL | −21 °C | 5–11 panels per string (best 10) |
| Denver, CO | −23.6 °C | 5–11 panels per string (best 10) |
| Atlanta, GA | −9.5 °C | 5–11 panels per string (best 10) |
| Dallas, TX | −7.1 °C | 5–11 panels per string (best 10) |
| Phoenix, AZ | 1.3 °C | 5–12 panels per string (best 11) |
| Miami, FL | 5.9 °C | 5–12 panels per string (best 11) |
Common system sizes
How Canadian Solar HiKu6 CS6R-410MS panels lay out on the EG4 12000XP for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 15 | 1 × 8 + 1 × 7 panels on 1 inverter | 6.15 kWp | 0.51 |
| About 8 kW | 20 | 2 strings of 10 on 1 inverter | 8.20 kWp | 0.68 |
| About 10 kW | 24 | 3 strings of 8 on 1 inverter | 9.84 kWp | 0.82 |