Home › Compatibility › Canadian Solar CS3Y-445PB-AG + APsystems DS3

Canadian Solar CS3Y-445PB-AG with APsystems DS3

Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.

✓

Compatible

Yes. Each DS3 takes 2 panels, and up to 4 units fit on one 20 A branch circuit (8 panels). DC/AC ratio 1.01.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2 panels per unit
Chicago, IL−21 °C2 panels per unit
Denver, CO−23.6 °C2 panels per unit
Atlanta, GA−9.5 °C2 panels per unit
Dallas, TX−7.1 °C2 panels per unit
Phoenix, AZ1.3 °C2 panels per unit
Miami, FL5.9 °C2 panels per unit

Common system sizes

How Canadian Solar CS3Y-445PB-AG panels lay out on the APsystems DS3 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW137 × DS3 on 2 branch circuits5.79 kWp0.94
About 8 kW189 × DS3 on 3 branch circuits8.01 kWp1.01
About 10 kW2211 × DS3 on 3 branch circuits9.79 kWp1.01