Home › Compatibility › Canadian Solar CS6.2-48TM-445H + APsystems DS3-S
Canadian Solar CS6.2-48TM-445H with APsystems DS3-S
Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.
✓
Compatible
Yes. Each DS3-S takes 2 panels, and up to 6 units fit on one 20 A branch circuit (12 panels). DC/AC ratio 1.39.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Max input voltageVoc at the record low is 37.4 V, within the 60 V limit (62%).
- ✓ MPPT window, hot dayVmp on the hottest day is 25.8 V, inside 22–48 V.
- ✓ MPPT window, cold dayVmp on the coldest day is 34.0 V, inside the MPPT range.
- ✓ Input currentImp 14.64 A is within the 16 A max input current. The datasheet gives no separate Isc limit.
- ✓ Module power pairing445 W is inside the recommended 250–480 (DC/AC 1.39).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 2 panels per unit |
| Chicago, IL | −21 °C | 2 panels per unit |
| Denver, CO | −23.6 °C | 2 panels per unit |
| Atlanta, GA | −9.5 °C | 2 panels per unit |
| Dallas, TX | −7.1 °C | 2 panels per unit |
| Phoenix, AZ | 1.3 °C | 2 panels per unit |
| Miami, FL | 5.9 °C | 2 panels per unit |
Common system sizes
How Canadian Solar CS6.2-48TM-445H panels lay out on the APsystems DS3-S for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 13 | 7 × DS3-S on 2 branch circuits | 5.79 kWp | 1.29 |
| About 8 kW | 18 | 9 × DS3-S on 2 branch circuits | 8.01 kWp | 1.39 |
| About 10 kW | 22 | 11 × DS3-S on 2 branch circuits | 9.79 kWp | 1.39 |