Home › Compatibility › Canadian Solar TOPBiHiKu6 CS6.2-66TB-620 + SMA SBSE4.8-US-50

Canadian Solar TOPBiHiKu6 CS6.2-66TB-620 with SMA SBSE4.8-US-50

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–11 panels work. The longest string reaches 579 V on the coldest morning, under the 600 V inverter limit. One SMA SBSE4.8-US-50 takes up to 1 string of 10: 10 panels, 6.20 kWp DC, DC/AC ratio 1.29.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2–10 panels per string (best 9)
Chicago, IL−21 °C2–11 panels per string (best 10)
Denver, CO−23.6 °C2–11 panels per string (best 9)
Atlanta, GA−9.5 °C2–11 panels per string (best 10)
Dallas, TX−7.1 °C2–11 panels per string (best 10)
Phoenix, AZ1.3 °C2–11 panels per string (best 10)
Miami, FL5.9 °C2–11 panels per string (best 10)

Common system sizes

How Canadian Solar TOPBiHiKu6 CS6.2-66TB-620 panels lay out on the SMA SBSE4.8-US-50 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW101 string of 10 on 1 inverter6.20 kWp1.29
About 8 kW131 × 7 + 1 × 6 panels on 1 inverter8.06 kWp1.68
About 10 kW162 strings of 8 on 2 inverters9.92 kWp1.03