Canadian Solar TOPBiHiKu6 CS6.2-66TB-620 with SMA SBSE7.7-US-50
Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–11 panels work. The longest string reaches 579 V on the coldest morning, under the 600 V inverter limit. One SMA SBSE7.7-US-50 takes up to 2 strings of 10: 20 panels, 12.40 kWp DC, DC/AC ratio 1.61.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.
- Voc on the coldest morning48.4 V × (1 + -0.25%/°C × (−10 − 25)) = 52.63 V per panel.
- Vmp on the hottest afternoonCells reach 66.2 °C (40 °C air plus the NMOT rise), so Vmp drops from 41.2 V to 35.42 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string600 V inverter limit ÷ 52.63 V = 11 panels.
- Shortest string60 V MPPT minimum ÷ 35.42 V = 2 panels; start-up voltage needs 2.
- Strings per MPPTHot-day Isc 18.05 A per string, so the MPPT inputs take 1 + 1 + 1 + 1 string(s); expect about 10.4% current clipping at peak.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 2–10 panels per string (best 9) |
| Chicago, IL | −21 °C | 2–11 panels per string (best 10) |
| Denver, CO | −23.6 °C | 2–11 panels per string (best 9) |
| Atlanta, GA | −9.5 °C | 2–11 panels per string (best 10) |
| Dallas, TX | −7.1 °C | 2–11 panels per string (best 10) |
| Phoenix, AZ | 1.3 °C | 2–11 panels per string (best 10) |
| Miami, FL | 5.9 °C | 2–11 panels per string (best 10) |
Common system sizes
How Canadian Solar TOPBiHiKu6 CS6.2-66TB-620 panels lay out on the SMA SBSE7.7-US-50 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 10 | 1 string of 10 on 1 inverter | 6.20 kWp | 0.81 |
| About 8 kW | 13 | 1 × 7 + 1 × 6 panels on 1 inverter | 8.06 kWp | 1.05 |
| About 10 kW | 16 | 2 strings of 8 on 1 inverter | 9.92 kWp | 1.29 |