Home › Compatibility › Canadian Solar TOPBiHiKu6 CS6.2-66TB-620 + Sol-Ark 60K-3P-480V

Canadian Solar TOPBiHiKu6 CS6.2-66TB-620 with Sol-Ark 60K-3P-480V

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 5–18 panels work. The longest string reaches 947 V on the coldest morning, under the 1000 V inverter limit. One Sol-Ark 60K-3P-480V takes up to 6 strings of 18: 108 panels, 66.96 kWp DC, DC/AC ratio 1.12.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C5–18 panels per string (best 17)
Chicago, IL−21 °C5–18 panels per string (best 17)
Denver, CO−23.6 °C5–18 panels per string (best 17)
Atlanta, GA−9.5 °C5–19 panels per string (best 18)
Dallas, TX−7.1 °C5–19 panels per string (best 18)
Phoenix, AZ1.3 °C5–19 panels per string (best 19)
Miami, FL5.9 °C5–19 panels per string (best 19)

Common system sizes

How Canadian Solar TOPBiHiKu6 CS6.2-66TB-620 panels lay out on the Sol-Ark 60K-3P-480V for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded1208 strings of 15 on 1 inverter74.40 kWp1.24
2 inverters, fully loaded24016 strings of 15 on 2 inverters148.80 kWp1.24
4 inverters, fully loaded48032 strings of 15 on 4 inverters297.60 kWp1.24