Home › Compatibility › Canadian Solar TOPHiKu6 CS6.1-54TM-455H + Enphase IQ7A-72-2-US
Canadian Solar TOPHiKu6 CS6.1-54TM-455H with Enphase IQ7A-72-2-US
Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.
!
Compatible, with a caution
Yes. Each IQ7A-72-2-US takes 1 panel, and up to 11 units fit on one 20 A branch circuit (11 panels). DC/AC ratio 1.30. Check the MPPT window, hot day below.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Max input voltageVoc at the record low is 42.5 V, within the 58 V limit (73%).
- ! MPPT window, hot dayVmp drops to 28.0 V, below the 38 V MPPT minimum, so some output is lost on the hottest days.
- ✓ MPPT window, cold dayVmp on the coldest day is 37.2 V, inside the MPPT range.
- ✓ Start-up voltageHot-day Voc 34.6 V clears the 33 V start-up voltage.
- ✓ Module short-circuit currentIsc 14.61 A is within the 15 A max module Isc.
- ✓ Module power pairing455 W is inside the recommended 295–460 (DC/AC 1.30).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 1 panel per unit (check: MPPT window, hot day) |
| Chicago, IL | −21 °C | 1 panel per unit (check: MPPT window, hot day) |
| Denver, CO | −23.6 °C | 1 panel per unit (check: MPPT window, hot day) |
| Atlanta, GA | −9.5 °C | 1 panel per unit (check: MPPT window, hot day) |
| Dallas, TX | −7.1 °C | 1 panel per unit (check: MPPT window, hot day) |
| Phoenix, AZ | 1.3 °C | 1 panel per unit (check: MPPT window, hot day) |
| Miami, FL | 5.9 °C | 1 panel per unit (check: MPPT window, hot day) |
Common system sizes
How Canadian Solar TOPHiKu6 CS6.1-54TM-455H panels lay out on the Enphase IQ7A-72-2-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 13 | 13 × IQ7A-72-2-US on 2 branch circuits | 5.92 kWp | 1.30 |
| About 8 kW | 18 | 18 × IQ7A-72-2-US on 2 branch circuits | 8.19 kWp | 1.30 |
| About 10 kW | 22 | 22 × IQ7A-72-2-US on 2 branch circuits | 10.01 kWp | 1.30 |