Home › Compatibility › Canadian Solar TOPHiKu6 CS6.1-54TM-455H + SMA SBSE11.5-US-50

Canadian Solar TOPHiKu6 CS6.1-54TM-455H with SMA SBSE11.5-US-50

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 3–14 panels work. The longest string reaches 595 V on the coldest morning, under the 600 V inverter limit. One SMA SBSE11.5-US-50 takes up to 4 strings of 12: 48 panels, 21.84 kWp DC, DC/AC ratio 1.90.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C3–13 panels per string (best 12)
Chicago, IL−21 °C3–13 panels per string (best 12)
Denver, CO−23.6 °C3–13 panels per string (best 12)
Atlanta, GA−9.5 °C3–14 panels per string (best 12)
Dallas, TX−7.1 °C3–14 panels per string (best 13)
Phoenix, AZ1.3 °C3–14 panels per string (best 13)
Miami, FL5.9 °C3–14 panels per string (best 13)

Common system sizes

How Canadian Solar TOPHiKu6 CS6.1-54TM-455H panels lay out on the SMA SBSE11.5-US-50 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW131 string of 13 on 1 inverter5.92 kWp0.51
About 8 kW182 strings of 9 on 1 inverter8.19 kWp0.71
About 10 kW222 strings of 11 on 1 inverter10.01 kWp0.87