Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 3–14 panels work. The longest string reaches 583 V on the coldest morning, under the 600 V inverter limit. One Fronius Primo GEN24 7.7 Plus takes up to 2 strings of 13: 26 panels, 11.18 kWp DC, DC/AC ratio 1.46.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning38.42 V × (1 + -0.239%/°C × (−10 − 25)) = 41.63 V per panel.
- Vmp on the hottest afternoonCells reach 71.4 °C (40 °C air plus the NMOT rise), so Vmp drops from 32.45 V to 27.51 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string600 V inverter limit ÷ 41.63 V = 14 panels.
- Shortest string65 V MPPT minimum ÷ 27.51 V = 3 panels; start-up voltage needs 3.
- Strings per MPPTHot-day Isc 14.34 A per string, so the MPPT inputs take 2 + 2 string(s); expect about 20.7% current clipping at peak.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 3–13 panels per string (best 12) |
| Chicago, IL | −21 °C | 3–14 panels per string (best 12) |
| Denver, CO | −23.6 °C | 3–13 panels per string (best 12) |
| Atlanta, GA | −9.5 °C | 3–14 panels per string (best 13) |
| Dallas, TX | −7.1 °C | 3–14 panels per string (best 13) |
| Phoenix, AZ | 1.3 °C | 3–14 panels per string (best 13) |
| Miami, FL | 5.9 °C | 3–14 panels per string (best 13) |
Common system sizes
How Heliene 108HC-430 M10 NTYP SL panels lay out on the Fronius Primo GEN24 7.7 Plus for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 14 | 1 string of 14 on 1 inverter | 6.02 kWp | 0.78 |
| About 8 kW | 19 | 1 × 10 + 1 × 9 panels on 1 inverter | 8.17 kWp | 1.06 |
| About 10 kW | 23 | 1 × 12 + 1 × 11 panels on 1 inverter | 9.89 kWp | 1.29 |