Home › Compatibility › Hyundai HiN-S440XI + Tesla Powerwall 3

Hyundai HiN-S440XI with Tesla Powerwall 3

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–10 panels work. The longest string reaches 544 V on the coldest morning, under the 550 V inverter limit. One Tesla Powerwall 3 takes up to 4 strings of 10: 40 panels, 17.60 kWp DC, DC/AC ratio 1.53.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2–9 panels per string (best 9)
Chicago, IL−21 °C2–9 panels per string (best 9)
Denver, CO−23.6 °C2–9 panels per string (best 9)
Atlanta, GA−9.5 °C2–10 panels per string (best 10)
Dallas, TX−7.1 °C2–10 panels per string (best 10)
Phoenix, AZ1.3 °C2–10 panels per string (best 10)
Miami, FL5.9 °C2–10 panels per string (best 10)

Common system sizes

How Hyundai HiN-S440XI panels lay out on the Tesla Powerwall 3 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 1 inverter6.16 kWp0.54
About 8 kW182 strings of 9 on 1 inverter7.92 kWp0.69
About 10 kW232 × 8 + 1 × 7 panels on 1 inverter10.12 kWp0.88