Compatible

Yes, with the SolarEdge S440 optimizer on every panel. Strings of 8–16 panels work (best 13), each delivering up to 5,700 W. One SolarEdge SE10000H-US takes up to 3 strings of 13: 37 panels, 15.17 kWp DC, DC/AC ratio 1.52.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C8–16 panels per string (best 13)
Chicago, IL−21 °C8–16 panels per string (best 13)
Denver, CO−23.6 °C8–16 panels per string (best 13)
Atlanta, GA−9.5 °C8–16 panels per string (best 13)
Dallas, TX−7.1 °C8–16 panels per string (best 13)
Phoenix, AZ1.3 °C8–16 panels per string (best 13)
Miami, FL5.9 °C8–16 panels per string (best 13)

Common system sizes

How JA Solar JAM54S30-410/MR panels lay out on the SolarEdge SE10000H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW151 string of 15 on 1 inverter6.15 kWp0.61
About 8 kW202 strings of 10 on 1 inverter8.20 kWp0.82
About 10 kW242 strings of 12 on 1 inverter9.84 kWp0.98