JA Solar JAM54S31-405/MR with Sol-Ark 12K-2P-LL

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 6–12 panels work. The longest string reaches 487 V on the coldest morning, under the 500 V inverter limit. One Sol-Ark 12K-2P-LL takes up to 3 strings of 12: 36 panels, 14.58 kWp DC, DC/AC ratio 1.22.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C6–11 panels per string (best 11)
Chicago, IL−21 °C6–12 panels per string (best 11)
Denver, CO−23.6 °C6–11 panels per string (best 11)
Atlanta, GA−9.5 °C6–12 panels per string (best 12)
Dallas, TX−7.1 °C6–12 panels per string (best 12)
Phoenix, AZ1.3 °C6–12 panels per string (best 12)
Miami, FL5.9 °C6–12 panels per string (best 12)

Common system sizes

How JA Solar JAM54S31-405/MR panels lay out on the Sol-Ark 12K-2P-LL for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW151 × 8 + 1 × 7 panels on 1 inverter6.08 kWp0.51
About 8 kW202 strings of 10 on 1 inverter8.10 kWp0.67
About 10 kW251 × 9 + 2 × 8 panels on 1 inverter10.12 kWp0.84