Home › Compatibility › Jinko Solar Tiger Neo JKM580N-72HL4-BDV + APsystems DS3-L

Jinko Solar Tiger Neo JKM580N-72HL4-BDV with APsystems DS3-L

Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.

!

Compatible, with a caution

Yes. Each DS3-L takes 2 panels, and up to 5 units fit on one 20 A branch circuit (10 panels). DC/AC ratio 1.51. Check the Module power pairing below.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2 panels per unit (check: Module power pairing)
Chicago, IL−21 °C2 panels per unit (check: Module power pairing)
Denver, CO−23.6 °C2 panels per unit (check: Module power pairing)
Atlanta, GA−9.5 °C2 panels per unit (check: Module power pairing)
Dallas, TX−7.1 °C2 panels per unit (check: Module power pairing)
Phoenix, AZ1.3 °C2 panels per unit (check: Module power pairing)
Miami, FL5.9 °C2 panels per unit (check: Module power pairing)

Common system sizes

How Jinko Solar Tiger Neo JKM580N-72HL4-BDV panels lay out on the APsystems DS3-L for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW105 × DS3-L on 1 branch circuit5.80 kWp1.51
About 8 kW147 × DS3-L on 2 branch circuits8.12 kWp1.51
About 10 kW179 × DS3-L on 2 branch circuits9.86 kWp1.43