Home › Compatibility › Jinko Solar Tiger Neo JKM580N-72HL4-BDV + Hoymiles HMS-800-2T-NA
Jinko Solar Tiger Neo JKM580N-72HL4-BDV with Hoymiles HMS-800-2T-NA
Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.
!
Compatible, with a caution
Yes. Each HMS-800-2T-NA takes 2 panels, and up to 5 units fit on one 20 A branch circuit (10 panels). DC/AC ratio 1.61. Check the Input current; Module power pairing below.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.
- ✓ Max input voltageVoc at the record low is 56.0 V, within the 65 V limit (86%).
- ✓ MPPT window, hot dayVmp on the hottest day is 36.0 V, inside 16–60 V.
- ✓ MPPT window, cold dayVmp on the coldest day is 47.6 V, inside the MPPT range.
- ✓ Start-up voltageHot-day Voc 45.5 V clears the 25 V start-up voltage.
- ! Input currentImp 14.98 A is above the 14 A max input current, so some clipping. The datasheet gives no separate Isc limit.
- ! Module power pairing580 W is above the recommended 320–540 W, so expect midday clipping (DC/AC 1.61).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 2 panels per unit (check: Input current) |
| Chicago, IL | −21 °C | 2 panels per unit (check: Input current) |
| Denver, CO | −23.6 °C | 2 panels per unit (check: Input current) |
| Atlanta, GA | −9.5 °C | 2 panels per unit (check: Input current) |
| Dallas, TX | −7.1 °C | 2 panels per unit (check: Input current) |
| Phoenix, AZ | 1.3 °C | 2 panels per unit (check: Input current) |
| Miami, FL | 5.9 °C | 2 panels per unit (check: Input current) |
Common system sizes
How Jinko Solar Tiger Neo JKM580N-72HL4-BDV panels lay out on the Hoymiles HMS-800-2T-NA for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 10 | 5 × HMS-800-2T-NA on 1 branch circuit | 5.80 kWp | 1.61 |
| About 8 kW | 14 | 7 × HMS-800-2T-NA on 2 branch circuits | 8.12 kWp | 1.61 |
| About 10 kW | 17 | 9 × HMS-800-2T-NA on 2 branch circuits | 9.86 kWp | 1.52 |