Home › Compatibility › Jinko Solar Tiger Neo JKM590N-72HL4-BDV + SMA SB3.0-1SP-US-41

Jinko Solar Tiger Neo JKM590N-72HL4-BDV with SMA SB3.0-1SP-US-41

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 3–10 panels work. The longest string reaches 564 V on the coldest morning, under the 600 V inverter limit.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C3–10 panels per string (best 10)
Chicago, IL−21 °C3–10 panels per string (best 10)
Denver, CO−23.6 °C3–10 panels per string (best 10)
Atlanta, GA−9.5 °C3–10 panels per string (best 10)
Dallas, TX−7.1 °C3–10 panels per string (best 10)
Phoenix, AZ1.3 °C3–10 panels per string (best 10)
Miami, FL5.9 °C3–11 panels per string (best 11)

Common system sizes

How Jinko Solar Tiger Neo JKM590N-72HL4-BDV panels lay out on the SMA SB3.0-1SP-US-41 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW102 strings of 5 on 2 inverters5.90 kWp0.98
About 8 kW142 strings of 7 on 2 inverters8.26 kWp1.38
About 10 kW172 × 6 + 1 × 5 panels on 3 inverters10.03 kWp1.11