Home › Compatibility › LONGi Hi-MO 6 LR5-54HTB-435M + APsystems YC600

LONGi Hi-MO 6 LR5-54HTB-435M with APsystems YC600

Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.

!

Compatible, with a caution

Yes. Each YC600 takes 2 panels, and up to 7 units fit on one 20 A branch circuit (14 panels). DC/AC ratio 1.59. Check the Input current below.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2 panels per unit (check: Input current)
Chicago, IL−21 °C2 panels per unit (check: Input current)
Denver, CO−23.6 °C2 panels per unit (check: Input current)
Atlanta, GA−9.5 °C2 panels per unit (check: Input current)
Dallas, TX−7.1 °C2 panels per unit (check: Input current)
Phoenix, AZ1.3 °C2 panels per unit (check: Input current)
Miami, FL5.9 °C2 panels per unit (check: Input current)

Common system sizes

How LONGi Hi-MO 6 LR5-54HTB-435M panels lay out on the APsystems YC600 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW147 × YC600 on 1 branch circuit6.09 kWp1.59
About 8 kW189 × YC600 on 2 branch circuits7.83 kWp1.59
About 10 kW2312 × YC600 on 2 branch circuits10.01 kWp1.52