LONGi Hi-MO 6 LR5-54HTB-435M with SMA STP 50-US-41
Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 6–23 panels work. The longest string reaches 985 V on the coldest morning, under the 1000 V inverter limit. One SMA STP 50-US-41 takes up to 7 strings of 23: 161 panels, 70.03 kWp DC, DC/AC ratio 1.40.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning39.63 V × (1 + -0.23%/°C × (−10 − 25)) = 42.82 V per panel.
- Vmp on the hottest afternoonCells reach 71.2 °C (40 °C air plus the NMOT rise), so Vmp drops from 33.36 V to 28.11 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string1000 V inverter limit ÷ 42.82 V = 23 panels.
- Shortest string150 V MPPT minimum ÷ 28.11 V = 6 panels; start-up voltage needs 6.
- Strings per MPPTHot-day Isc 14.41 A per string, so the MPPT inputs take 2 + 2 + 2 + 2 + 2 + 2 string(s); expect about 30.5% current clipping at peak.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 6–22 panels per string (best 22) |
| Chicago, IL | −21 °C | 6–22 panels per string (best 22) |
| Denver, CO | −23.6 °C | 6–22 panels per string (best 22) |
| Atlanta, GA | −9.5 °C | 6–23 panels per string (best 23) |
| Dallas, TX | −7.1 °C | 6–23 panels per string (best 23) |
| Phoenix, AZ | 1.3 °C | 6–23 panels per string (best 23) |
| Miami, FL | 5.9 °C | 6–24 panels per string (best 24) |
Common system sizes
How LONGi Hi-MO 6 LR5-54HTB-435M panels lay out on the SMA STP 50-US-41 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| 1 inverter, fully loaded | 171 | 9 strings of 19 on 1 inverter | 74.39 kWp | 1.49 |
| 2 inverters, fully loaded | 342 | 18 strings of 19 on 2 inverters | 148.77 kWp | 1.49 |
| 4 inverters, fully loaded | 684 | 36 strings of 19 on 4 inverters | 297.54 kWp | 1.49 |