Home › Compatibility › LONGi Hi-MO 6 LR5-54HTB-435M + Solis S6-GC60K-US

LONGi Hi-MO 6 LR5-54HTB-435M with Solis S6-GC60K-US

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 7–23 panels work. The longest string reaches 985 V on the coldest morning, under the 1000 V inverter limit. One Solis S6-GC60K-US takes up to 8 strings of 23: 184 panels, 80.04 kWp DC, DC/AC ratio 1.33.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C7–22 panels per string (best 22)
Chicago, IL−21 °C7–22 panels per string (best 22)
Denver, CO−23.6 °C7–22 panels per string (best 22)
Atlanta, GA−9.5 °C7–23 panels per string (best 23)
Dallas, TX−7.1 °C7–23 panels per string (best 23)
Phoenix, AZ1.3 °C7–23 panels per string (best 23)
Miami, FL5.9 °C7–24 panels per string (best 24)

Common system sizes

How LONGi Hi-MO 6 LR5-54HTB-435M panels lay out on the Solis S6-GC60K-US for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded1848 strings of 23 on 1 inverter80.04 kWp1.33
2 inverters, fully loaded36816 strings of 23 on 2 inverters160.08 kWp1.33
4 inverters, fully loaded73632 strings of 23 on 4 inverters320.16 kWp1.33