Home › Compatibility › Maxeon SPR-MAX3-430 + SMA SB5.0-1SP-US-41

Maxeon SPR-MAX3-430 with SMA SB5.0-1SP-US-41

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–6 panels work. The longest string reaches 528 V on the coldest morning, under the 600 V inverter limit. One SMA SB5.0-1SP-US-41 takes up to 3 strings of 6: 18 panels, 7.74 kWp DC, DC/AC ratio 1.55.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2–6 panels per string (best 6)
Chicago, IL−21 °C2–6 panels per string (best 6)
Denver, CO−23.6 °C2–6 panels per string (best 6)
Atlanta, GA−9.5 °C2–6 panels per string (best 6)
Dallas, TX−7.1 °C2–6 panels per string (best 6)
Phoenix, AZ1.3 °C2–6 panels per string (best 6)
Miami, FL5.9 °C2–7 panels per string (best 7)

Common system sizes

How Maxeon SPR-MAX3-430 panels lay out on the SMA SB5.0-1SP-US-41 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 × 5 + 1 × 4 panels on 1 inverter6.02 kWp1.20
About 8 kW193 × 5 + 1 × 4 panels on 2 inverters8.17 kWp0.82
About 10 kW233 × 6 + 1 × 5 panels on 2 inverters9.89 kWp0.99