Home › Compatibility › Maxeon SPR-MAX6-435 + EG4 FlexBOSS21

Maxeon SPR-MAX6-435 with EG4 FlexBOSS21

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 5–11 panels work. The longest string reaches 573 V on the coldest morning, under the 600 V inverter limit. One EG4 FlexBOSS21 takes up to 5 strings of 9: 45 panels, 19.57 kWp DC, DC/AC ratio 1.22.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C5–11 panels per string (best 9)
Chicago, IL−21 °C5–11 panels per string (best 9)
Denver, CO−23.6 °C5–11 panels per string (best 9)
Atlanta, GA−9.5 °C5–11 panels per string (best 9)
Dallas, TX−7.1 °C5–11 panels per string (best 9)
Phoenix, AZ1.3 °C5–11 panels per string (best 10)
Miami, FL5.9 °C5–11 panels per string (best 10)

Common system sizes

How Maxeon SPR-MAX6-435 panels lay out on the EG4 FlexBOSS21 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded455 strings of 9 on 1 inverter19.57 kWp1.22
2 inverters, fully loaded9010 strings of 9 on 2 inverters39.15 kWp1.22
4 inverters, fully loaded18020 strings of 9 on 4 inverters78.30 kWp1.22