Home › Compatibility › Maxeon SPR-MAX6-435 + Fronius Primo GEN24 10.0 Plus

Maxeon SPR-MAX6-435 with Fronius Primo GEN24 10.0 Plus

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–11 panels work. The longest string reaches 573 V on the coldest morning, under the 600 V inverter limit. One Fronius Primo GEN24 10.0 Plus takes up to 3 strings of 10: 30 panels, 13.05 kWp DC, DC/AC ratio 1.31.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2–11 panels per string (best 10)
Chicago, IL−21 °C2–11 panels per string (best 10)
Denver, CO−23.6 °C2–11 panels per string (best 10)
Atlanta, GA−9.5 °C2–11 panels per string (best 10)
Dallas, TX−7.1 °C2–11 panels per string (best 10)
Phoenix, AZ1.3 °C2–11 panels per string (best 11)
Miami, FL5.9 °C2–11 panels per string (best 11)

Common system sizes

How Maxeon SPR-MAX6-435 panels lay out on the Fronius Primo GEN24 10.0 Plus for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 1 inverter6.09 kWp0.61
About 8 kW182 strings of 9 on 1 inverter7.83 kWp0.78
About 10 kW232 × 8 + 1 × 7 panels on 1 inverter10.01 kWp1.00