Home › Compatibility › Maxeon SPR-MAX6-435 + SolarEdge SE10000H-US

Maxeon SPR-MAX6-435 with SolarEdge SE10000H-US

Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.

✓

Compatible

Yes, with the SolarEdge S440 optimizer on every panel. Strings of 8–15 panels work (best 13), each delivering up to 5,700 W. One SolarEdge SE10000H-US takes up to 3 strings of 13: 35 panels, 15.22 kWp DC, DC/AC ratio 1.52.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C8–15 panels per string (best 13)
Chicago, IL−21 °C8–15 panels per string (best 13)
Denver, CO−23.6 °C8–15 panels per string (best 13)
Atlanta, GA−9.5 °C8–15 panels per string (best 13)
Dallas, TX−7.1 °C8–15 panels per string (best 13)
Phoenix, AZ1.3 °C8–15 panels per string (best 13)
Miami, FL5.9 °C8–15 panels per string (best 13)

Common system sizes

How Maxeon SPR-MAX6-435 panels lay out on the SolarEdge SE10000H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW141 string of 14 on 1 inverter6.09 kWp0.61
About 8 kW182 strings of 9 on 1 inverter7.83 kWp0.78
About 10 kW231 × 12 + 1 × 11 panels on 1 inverter10.01 kWp1.00