Meyer Burger Meyer Burger White 400W with SMA SB5.0-1SP-US-41
Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 4–12 panels work. The longest string reaches 580 V on the coldest morning, under the 600 V inverter limit. One SMA SB5.0-1SP-US-41 takes up to 1 string of 12: 12 panels, 4.80 kWp DC, DC/AC ratio 0.96.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning44.7 V × (1 + -0.233%/°C × (−10 − 25)) = 48.35 V per panel.
- Vmp on the hottest afternoonCells reach 72.8 °C (40 °C air plus the NMOT rise), so Vmp drops from 38.2 V to 33.04 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string600 V inverter limit ÷ 48.35 V = 12 panels.
- Shortest string100 V MPPT minimum ÷ 33.04 V = 4 panels; start-up voltage needs 4.
- Strings per MPPTHot-day Isc 11.29 A per string, so the MPPT inputs take 1 + 1 + 1 string(s); expect about 5.0% current clipping at peak.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 4–11 panels per string (best 11) |
| Chicago, IL | −21 °C | 4–12 panels per string (best 12) |
| Denver, CO | −23.6 °C | 4–12 panels per string (best 12) |
| Atlanta, GA | −9.5 °C | 4–12 panels per string (best 12) |
| Dallas, TX | −7.1 °C | 4–12 panels per string (best 12) |
| Phoenix, AZ | 1.3 °C | 4–12 panels per string (best 12) |
| Miami, FL | 5.9 °C | 4–12 panels per string (best 12) |
Common system sizes
How Meyer Burger Meyer Burger White 400W panels lay out on the SMA SB5.0-1SP-US-41 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 15 | 1 × 8 + 1 × 7 panels on 1 inverter | 6.00 kWp | 1.20 |
| About 8 kW | 20 | 2 strings of 10 on 1 inverter | 8.00 kWp | 1.60 |
| About 10 kW | 25 | 1 × 9 + 2 × 8 panels on 2 inverters | 10.00 kWp | 1.00 |