Home › Compatibility › Mission Solar MSX10-435HN0B + SMA SBSE4.8-US-50

Mission Solar MSX10-435HN0B with SMA SBSE4.8-US-50

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 3–13 panels work. The longest string reaches 559 V on the coldest morning, under the 600 V inverter limit. One SMA SBSE4.8-US-50 takes up to 1 string of 12: 12 panels, 5.22 kWp DC, DC/AC ratio 1.09.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C3–13 panels per string (best 12)
Chicago, IL−21 °C3–13 panels per string (best 12)
Denver, CO−23.6 °C3–13 panels per string (best 12)
Atlanta, GA−9.5 °C3–13 panels per string (best 12)
Dallas, TX−7.1 °C3–14 panels per string (best 12)
Phoenix, AZ1.3 °C3–14 panels per string (best 13)
Miami, FL5.9 °C3–14 panels per string (best 13)

Common system sizes

How Mission Solar MSX10-435HN0B panels lay out on the SMA SBSE4.8-US-50 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 1 inverter6.09 kWp1.27
About 8 kW182 strings of 9 on 1 inverter7.83 kWp1.63
About 10 kW231 × 12 + 1 × 11 panels on 2 inverters10.01 kWp1.04