Home › Compatibility › Mission Solar MSX10-445HN0B + SMA SB7.7-1SP-US-41

Mission Solar MSX10-445HN0B with SMA SB7.7-1SP-US-41

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 4–13 panels work. The longest string reaches 567 V on the coldest morning, under the 600 V inverter limit. One SMA SB7.7-1SP-US-41 takes up to 2 strings of 13: 26 panels, 11.57 kWp DC, DC/AC ratio 1.51.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C4–13 panels per string (best 13)
Chicago, IL−21 °C4–13 panels per string (best 13)
Denver, CO−23.6 °C4–13 panels per string (best 13)
Atlanta, GA−9.5 °C4–13 panels per string (best 13)
Dallas, TX−7.1 °C4–13 panels per string (best 13)
Phoenix, AZ1.3 °C4–14 panels per string (best 14)
Miami, FL5.9 °C4–14 panels per string (best 14)

Common system sizes

How Mission Solar MSX10-445HN0B panels lay out on the SMA SB7.7-1SP-US-41 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW131 string of 13 on 1 inverter5.79 kWp0.75
About 8 kW182 strings of 9 on 1 inverter8.01 kWp1.04
About 10 kW222 strings of 11 on 1 inverter9.79 kWp1.27