Home › Compatibility › Qcells Q.PEAK DUO ML-G10+ 410 + APsystems DS3
Qcells Q.PEAK DUO ML-G10+ 410 with APsystems DS3
Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.
!
Compatible, with a caution
Yes. Each DS3 takes 2 panels, and up to 4 units fit on one 20 A branch circuit (8 panels). DC/AC ratio 0.93. Check the MPPT window, hot day below.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Max input voltageVoc at the record low is 49.8 V, within the 60 V limit (83%).
- ! MPPT window, hot dayVmp drops to 30.6 V, below the 32 V MPPT minimum, so some output is lost on the hottest days.
- ✓ MPPT window, cold dayVmp on the coldest day is 43.0 V, inside the MPPT range.
- ✓ Input currentImp 10.89 A is within the 20 A max input current. The datasheet gives no separate Isc limit.
- ✓ Module power pairing410 W is inside the recommended 300–660 (DC/AC 0.93).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 2 panels per unit (check: MPPT window, hot day) |
| Chicago, IL | −21 °C | 2 panels per unit (check: MPPT window, hot day) |
| Denver, CO | −23.6 °C | 2 panels per unit (check: MPPT window, hot day) |
| Atlanta, GA | −9.5 °C | 2 panels per unit (check: MPPT window, hot day) |
| Dallas, TX | −7.1 °C | 2 panels per unit (check: MPPT window, hot day) |
| Phoenix, AZ | 1.3 °C | 2 panels per unit (check: MPPT window, hot day) |
| Miami, FL | 5.9 °C | 2 panels per unit (check: MPPT window, hot day) |
Common system sizes
How Qcells Q.PEAK DUO ML-G10+ 410 panels lay out on the APsystems DS3 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 15 | 8 × DS3 on 2 branch circuits | 6.15 kWp | 0.87 |
| About 8 kW | 20 | 10 × DS3 on 3 branch circuits | 8.20 kWp | 0.93 |
| About 10 kW | 24 | 12 × DS3 on 3 branch circuits | 9.84 kWp | 0.93 |