Home › Compatibility › Qcells Q.PEAK DUO XL-G11S.3/BFG 590 + NEP BDM-600X
Qcells Q.PEAK DUO XL-G11S.3/BFG 590 with NEP BDM-600X
Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.
!
Compatible, with a caution
Yes. Each BDM-600X takes 2 panels, and up to 6 units fit on one 20 A branch circuit (12 panels). DC/AC ratio 2.03. Check the Input current; Module power pairing below.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 9.5%.
- ✓ Max input voltageVoc at the record low is 58.7 V, within the 60 V limit (98%).
- ✓ MPPT window, hot dayVmp on the hottest day is 37.7 V, inside 22–55 V.
- ✓ MPPT window, cold dayVmp on the coldest day is 50.9 V, inside the MPPT range.
- ! Input currentImp 14.37 A is above the 14 A max input current, so some clipping. The datasheet gives no separate Isc limit.
- ! Module power pairing590 W is above the recommended max 450 W, so expect midday clipping (DC/AC 2.03).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | Not compatible: Max input voltage |
| Chicago, IL | −21 °C | Not compatible: Max input voltage |
| Denver, CO | −23.6 °C | Not compatible: Max input voltage |
| Atlanta, GA | −9.5 °C | 2 panels per unit (check: Input current) |
| Dallas, TX | −7.1 °C | 2 panels per unit (check: Input current) |
| Phoenix, AZ | 1.3 °C | 2 panels per unit (check: Input current) |
| Miami, FL | 5.9 °C | 2 panels per unit (check: Input current) |
Common system sizes
How Qcells Q.PEAK DUO XL-G11S.3/BFG 590 panels lay out on the NEP BDM-600X for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 10 | 5 × BDM-600X on 1 branch circuit | 5.90 kWp | 2.03 |
| About 8 kW | 14 | 7 × BDM-600X on 2 branch circuits | 8.26 kWp | 2.03 |
| About 10 kW | 17 | 9 × BDM-600X on 2 branch circuits | 10.03 kWp | 1.92 |