Home › Compatibility › Qcells Q.PEAK DUO XL-G11S.3/BFG 590 + SMA STP 62-US-41

Qcells Q.PEAK DUO XL-G11S.3/BFG 590 with SMA STP 62-US-41

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 4–17 panels work. The longest string reaches 997 V on the coldest morning, under the 1000 V inverter limit. One SMA STP 62-US-41 takes up to 9 strings of 17: 153 panels, 90.27 kWp DC, DC/AC ratio 1.44.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 9.5%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C4–16 panels per string (best 16)
Chicago, IL−21 °C4–16 panels per string (best 16)
Denver, CO−23.6 °C4–16 panels per string (best 16)
Atlanta, GA−9.5 °C4–17 panels per string (best 17)
Dallas, TX−7.1 °C4–17 panels per string (best 17)
Phoenix, AZ1.3 °C4–17 panels per string (best 17)
Miami, FL5.9 °C4–17 panels per string (best 17)

Common system sizes

How Qcells Q.PEAK DUO XL-G11S.3/BFG 590 panels lay out on the SMA STP 62-US-41 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded15612 strings of 13 on 1 inverter92.04 kWp1.47
2 inverters, fully loaded31224 strings of 13 on 2 inverters184.08 kWp1.47
4 inverters, fully loaded62448 strings of 13 on 4 inverters368.16 kWp1.47