Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–14 panels work. The longest string reaches 996 V on the coldest morning, under the 1000 V inverter limit. One Fronius Primo 12.5-1 takes up to 2 strings of 13: 26 panels, 12.22 kWp DC, DC/AC ratio 0.98.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2–13 panels per string (best 12)
Chicago, IL−21 °C2–13 panels per string (best 12)
Denver, CO−23.6 °C2–13 panels per string (best 12)
Atlanta, GA−9.5 °C2–14 panels per string (best 13)
Dallas, TX−7.1 °C2–14 panels per string (best 13)
Phoenix, AZ1.3 °C2–14 panels per string (best 13)
Miami, FL5.9 °C2–14 panels per string (best 13)

Common system sizes

How REC Alpha Pure-RX REC470AA panels lay out on the Fronius Primo 12.5-1 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW131 string of 13 on 1 inverter6.11 kWp0.49
About 8 kW171 × 9 + 1 × 8 panels on 1 inverter7.99 kWp0.64
About 10 kW211 × 11 + 1 × 10 panels on 1 inverter9.87 kWp0.79