Home › Compatibility › REC Alpha Pure-RX REC470AA + Fronius Symo 24.0-3 480

REC Alpha Pure-RX REC470AA with Fronius Symo 24.0-3 480

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 5–14 panels work. The longest string reaches 996 V on the coldest morning, under the 1000 V inverter limit. One Fronius Symo 24.0-3 480 takes up to 5 strings of 13: 65 panels, 30.55 kWp DC, DC/AC ratio 1.27.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C5–13 panels per string (best 12)
Chicago, IL−21 °C5–13 panels per string (best 12)
Denver, CO−23.6 °C5–13 panels per string (best 12)
Atlanta, GA−9.5 °C5–14 panels per string (best 13)
Dallas, TX−7.1 °C5–14 panels per string (best 13)
Phoenix, AZ1.3 °C5–14 panels per string (best 13)
Miami, FL5.9 °C5–14 panels per string (best 13)

Common system sizes

How REC Alpha Pure-RX REC470AA panels lay out on the Fronius Symo 24.0-3 480 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded655 strings of 13 on 1 inverter30.55 kWp1.27
2 inverters, fully loaded13010 strings of 13 on 2 inverters61.10 kWp1.27
4 inverters, fully loaded26020 strings of 13 on 4 inverters122.20 kWp1.27