Home › Compatibility › REC Alpha Pure-RX REC470AA + Sol-Ark 5K-1P-N

REC Alpha Pure-RX REC470AA with Sol-Ark 5K-1P-N

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 4–7 panels work. The longest string reaches 498 V on the coldest morning, under the 500 V inverter limit. One Sol-Ark 5K-1P-N takes up to 3 strings of 6: 18 panels, 8.46 kWp DC, DC/AC ratio 1.76.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C4–6 panels per string (best 6)
Chicago, IL−21 °C4–6 panels per string (best 6)
Denver, CO−23.6 °C4–6 panels per string (best 6)
Atlanta, GA−9.5 °C4–7 panels per string (best 6)
Dallas, TX−7.1 °C4–7 panels per string (best 7)
Phoenix, AZ1.3 °C4–7 panels per string (best 7)
Miami, FL5.9 °C4–7 panels per string (best 7)

Common system sizes

How REC Alpha Pure-RX REC470AA panels lay out on the Sol-Ark 5K-1P-N for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW131 × 7 + 1 × 6 panels on 1 inverter6.11 kWp1.27
About 8 kW172 × 6 + 1 × 5 panels on 1 inverter7.99 kWp1.66
About 10 kW213 strings of 7 on 1 inverter9.87 kWp2.06