Home › Compatibility › REC REC405AA Pure + Enphase IQ8MC-72-M-US
REC REC405AA Pure with Enphase IQ8MC-72-M-US
Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.
!
Compatible, with a caution
Yes. Each IQ8MC-72-M-US takes 1 panel, and up to 12 units fit on one 20 A branch circuit (12 panels). DC/AC ratio 1.27. Check the MPPT window, cold day below.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Max input voltageVoc at the record low is 52.9 V, within the 60 V limit (88%).
- ✓ MPPT window, hot dayVmp on the hottest day is 36.7 V, inside 25–45 V.
- ! MPPT window, cold dayVmp rises to 46.7 V on cold days, above the 45 V MPPT maximum, so tracking is off-peak then.
- ✓ Start-up voltageHot-day Voc 43.6 V clears the 22 V start-up voltage.
- ✓ Module short-circuit currentIsc 10.30 A is within the 20 A max module Isc.
- ✓ Module power pairing405 W is inside the recommended 260–460 (DC/AC 1.27).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 1 panel per unit (check: MPPT window, cold day) |
| Chicago, IL | −21 °C | 1 panel per unit (check: MPPT window, cold day) |
| Denver, CO | −23.6 °C | 1 panel per unit (check: MPPT window, cold day) |
| Atlanta, GA | −9.5 °C | 1 panel per unit (check: MPPT window, cold day) |
| Dallas, TX | −7.1 °C | 1 panel per unit (check: MPPT window, cold day) |
| Phoenix, AZ | 1.3 °C | 1 panel per unit (check: MPPT window, cold day) |
| Miami, FL | 5.9 °C | 1 panel per unit |
Common system sizes
How REC REC405AA Pure panels lay out on the Enphase IQ8MC-72-M-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 15 | 15 × IQ8MC-72-M-US on 2 branch circuits | 6.08 kWp | 1.27 |
| About 8 kW | 20 | 20 × IQ8MC-72-M-US on 2 branch circuits | 8.10 kWp | 1.27 |
| About 10 kW | 25 | 25 × IQ8MC-72-M-US on 3 branch circuits | 10.12 kWp | 1.27 |