Home › Compatibility › REC REC450AA Pure-RX + SolarEdge SE3800H-US

REC REC450AA Pure-RX with SolarEdge SE3800H-US

Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.

✓

Compatible

Yes, with the SolarEdge S500B optimizer on every panel. Strings of 6–13 panels work (best 12), each delivering up to 5,700 W. One SolarEdge SE3800H-US takes up to 2 strings of 12: 13 panels, 5.85 kWp DC, DC/AC ratio 1.54.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C6–13 panels per string (best 12)
Chicago, IL−21 °C6–13 panels per string (best 12)
Denver, CO−23.6 °C6–13 panels per string (best 12)
Atlanta, GA−9.5 °C6–13 panels per string (best 12)
Dallas, TX−7.1 °C6–13 panels per string (best 12)
Phoenix, AZ1.3 °C6–13 panels per string (best 12)
Miami, FL5.9 °C6–13 panels per string (best 12)

Common system sizes

How REC REC450AA Pure-RX panels lay out on the SolarEdge SE3800H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW131 string of 13 on 1 inverter5.85 kWp1.54
About 8 kW182 strings of 9 on 2 inverters8.10 kWp1.07
About 10 kW222 strings of 11 on 2 inverters9.90 kWp1.30