Compatible, with a caution
Yes. Each IQ7-60-2-US takes 1 panel, and up to 16 units fit on one 20 A branch circuit (16 panels). DC/AC ratio 1.79. Check the MPPT window, cold day; Module power pairing below.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Max input voltageVoc at the record low is 42.2 V, within the 48 V limit (88%).
- ✓ MPPT window, hot dayVmp on the hottest day is 28.2 V, inside 27–37 V.
- ! MPPT window, cold dayVmp rises to 37.1 V on cold days, above the 37 V MPPT maximum, so tracking is off-peak then.
- ✓ Start-up voltageHot-day Voc 34.6 V clears the 22 V start-up voltage.
- ✓ Module short-circuit currentIsc 13.87 A is within the 15 A max module Isc.
- ! Module power pairing430 W is above the recommended 235–350 W, so expect midday clipping (DC/AC 1.79).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 1 panel per unit (check: MPPT window, cold day) |
| Chicago, IL | −21 °C | 1 panel per unit (check: MPPT window, cold day) |
| Denver, CO | −23.6 °C | 1 panel per unit (check: MPPT window, cold day) |
| Atlanta, GA | −9.5 °C | 1 panel per unit (check: MPPT window, cold day) |
| Dallas, TX | −7.1 °C | 1 panel per unit (check: Module power pairing) |
| Phoenix, AZ | 1.3 °C | 1 panel per unit (check: Module power pairing) |
| Miami, FL | 5.9 °C | 1 panel per unit (check: Module power pairing) |
Common system sizes
How Silfab Prime SIL-430 QD panels lay out on the Enphase IQ7-60-2-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 14 | 14 × IQ7-60-2-US on 1 branch circuit | 6.02 kWp | 1.79 |
| About 8 kW | 19 | 19 × IQ7-60-2-US on 2 branch circuits | 8.17 kWp | 1.79 |
| About 10 kW | 23 | 23 × IQ7-60-2-US on 2 branch circuits | 9.89 kWp | 1.79 |