Silfab Prime SIL-430 QD with Sol-Ark 30K-3P-208V
Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 6–13 panels work. The longest string reaches 548 V on the coldest morning, under the 550 V inverter limit. One Sol-Ark 30K-3P-208V takes up to 6 strings of 13: 78 panels, 33.54 kWp DC, DC/AC ratio 1.12.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning38.91 V × (1 + -0.24%/°C × (−10 − 25)) = 42.18 V per panel.
- Vmp on the hottest afternoonCells reach 71.2 °C (40 °C air plus the NMOT rise), so Vmp drops from 33.25 V to 28.18 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string550 V inverter limit ÷ 42.18 V = 13 panels.
- Shortest string150 V MPPT minimum ÷ 28.18 V = 6 panels; start-up voltage needs 6.
- Strings per MPPTHot-day Isc 14.13 A per string, so the MPPT inputs take 2 + 2 + 2 + 2 string(s).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 6–12 panels per string (best 12) |
| Chicago, IL | −21 °C | 6–12 panels per string (best 12) |
| Denver, CO | −23.6 °C | 6–12 panels per string (best 12) |
| Atlanta, GA | −9.5 °C | 6–13 panels per string (best 13) |
| Dallas, TX | −7.1 °C | 6–13 panels per string (best 13) |
| Phoenix, AZ | 1.3 °C | 6–13 panels per string (best 13) |
| Miami, FL | 5.9 °C | 6–13 panels per string (best 13) |
Common system sizes
How Silfab Prime SIL-430 QD panels lay out on the Sol-Ark 30K-3P-208V for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| 1 inverter, fully loaded | 88 | 8 strings of 11 on 1 inverter | 37.84 kWp | 1.26 |
| 2 inverters, fully loaded | 176 | 16 strings of 11 on 2 inverters | 75.68 kWp | 1.26 |
| 4 inverters, fully loaded | 352 | 32 strings of 11 on 4 inverters | 151.36 kWp | 1.26 |