Home › Compatibility › Silfab Prime SIL-430 QD + SolarEdge SE3000H-US
Silfab Prime SIL-430 QD with SolarEdge SE3000H-US
Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.
✓
Compatible
Yes, with the SolarEdge S440 optimizer on every panel. Strings of 8–10 panels work (best 10), each delivering up to 4,650 W. One SolarEdge SE3000H-US takes up to 1 string of 10: 10 panels, 4.30 kWp DC, DC/AC ratio 1.43.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Module power430 W is within the S440 rating of 440 W.
- ✓ Max input voltageVoc at the record low is 42.2 V, within the 60 V optimizer limit.
- ✓ MPPT windowVmp stays inside 8–60 V from the coldest to the hottest day.
- ✓ Module short-circuit currentIsc 13.87 A is within the 15 A limit.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 8–10 panels per string (best 10) |
| Chicago, IL | −21 °C | 8–10 panels per string (best 10) |
| Denver, CO | −23.6 °C | 8–10 panels per string (best 10) |
| Atlanta, GA | −9.5 °C | 8–10 panels per string (best 10) |
| Dallas, TX | −7.1 °C | 8–10 panels per string (best 10) |
| Phoenix, AZ | 1.3 °C | 8–10 panels per string (best 10) |
| Miami, FL | 5.9 °C | 8–10 panels per string (best 10) |
Common system sizes
How Silfab Prime SIL-430 QD panels lay out on the SolarEdge SE3000H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | Each string needs at least 8 optimizers, but this split gives only 7 panels per string. Add panels or use fewer strings. | |||
| About 8 kW | 19 | 1 × 10 + 1 × 9 panels on 2 inverters | 8.17 kWp | 1.36 |
| About 10 kW | Each string needs at least 8 optimizers, but this split gives only 7 panels per string. Add panels or use fewer strings. | |||