Silfab Prime SIL-430 QD with SolarEdge SE3000H-US

Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.

✓

Compatible

Yes, with the SolarEdge S440 optimizer on every panel. Strings of 8–10 panels work (best 10), each delivering up to 4,650 W. One SolarEdge SE3000H-US takes up to 1 string of 10: 10 panels, 4.30 kWp DC, DC/AC ratio 1.43.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C8–10 panels per string (best 10)
Chicago, IL−21 °C8–10 panels per string (best 10)
Denver, CO−23.6 °C8–10 panels per string (best 10)
Atlanta, GA−9.5 °C8–10 panels per string (best 10)
Dallas, TX−7.1 °C8–10 panels per string (best 10)
Phoenix, AZ1.3 °C8–10 panels per string (best 10)
Miami, FL5.9 °C8–10 panels per string (best 10)

Common system sizes

How Silfab Prime SIL-430 QD panels lay out on the SolarEdge SE3000H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kWEach string needs at least 8 optimizers, but this split gives only 7 panels per string. Add panels or use fewer strings.
About 8 kW191 × 10 + 1 × 9 panels on 2 inverters8.17 kWp1.36
About 10 kWEach string needs at least 8 optimizers, but this split gives only 7 panels per string. Add panels or use fewer strings.