Home › Compatibility › Silfab SIL-410NU + SolarEdge SE6000H-US
Silfab SIL-410NU with SolarEdge SE6000H-US
Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.
✓
Compatible
Yes, with the SolarEdge S440 optimizer on every panel. Strings of 8–13 panels work (best 13), each delivering up to 5,700 W. One SolarEdge SE6000H-US takes up to 2 strings of 13: 22 panels, 9.02 kWp DC, DC/AC ratio 1.50.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Module power410 W is within the S440 rating of 440 W.
- ✓ Max input voltageVoc at the record low is 54.1 V, within the 60 V optimizer limit.
- ✓ MPPT windowVmp stays inside 8–60 V from the coldest to the hottest day.
- ✓ Module short-circuit currentIsc 10.63 A is within the 15 A limit.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 8–13 panels per string (best 13) |
| Chicago, IL | −21 °C | 8–13 panels per string (best 13) |
| Denver, CO | −23.6 °C | 8–13 panels per string (best 13) |
| Atlanta, GA | −9.5 °C | 8–13 panels per string (best 13) |
| Dallas, TX | −7.1 °C | 8–13 panels per string (best 13) |
| Phoenix, AZ | 1.3 °C | 8–13 panels per string (best 13) |
| Miami, FL | 5.9 °C | 8–13 panels per string (best 13) |
Common system sizes
How Silfab SIL-410NU panels lay out on the SolarEdge SE6000H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | Each string needs at least 8 optimizers, but this split gives only 7 panels per string. Add panels or use fewer strings. | |||
| About 8 kW | 20 | 2 strings of 10 on 1 inverter | 8.20 kWp | 1.37 |
| About 10 kW | 24 | 2 strings of 12 on 2 inverters | 9.84 kWp | 0.82 |