Home › Compatibility › Silfab SIL-420HU + Fronius Primo GEN24 7.7 Plus

Silfab SIL-420HU with Fronius Primo GEN24 7.7 Plus

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–11 panels work. The longest string reaches 591 V on the coldest morning, under the 600 V inverter limit. One Fronius Primo GEN24 7.7 Plus takes up to 2 strings of 10: 20 panels, 8.40 kWp DC, DC/AC ratio 1.09.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2–10 panels per string (best 9)
Chicago, IL−21 °C2–10 panels per string (best 10)
Denver, CO−23.6 °C2–10 panels per string (best 9)
Atlanta, GA−9.5 °C2–11 panels per string (best 10)
Dallas, TX−7.1 °C2–11 panels per string (best 10)
Phoenix, AZ1.3 °C2–11 panels per string (best 10)
Miami, FL5.9 °C2–11 panels per string (best 10)

Common system sizes

How Silfab SIL-420HU panels lay out on the Fronius Primo GEN24 7.7 Plus for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 1 inverter5.88 kWp0.77
About 8 kW191 × 10 + 1 × 9 panels on 1 inverter7.98 kWp1.04
About 10 kW243 strings of 8 on 1 inverter10.08 kWp1.31