Home › Compatibility › SunPower SPR-M435 + SolarEdge SE11400H-US
SunPower SPR-M435 with SolarEdge SE11400H-US
Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.
✓
Compatible
Yes, with the SolarEdge S440 optimizer on every panel. Strings of 8–15 panels work (best 13), each delivering up to 5,700 W. One SolarEdge SE11400H-US takes up to 3 strings of 13: 39 panels, 16.96 kWp DC, DC/AC ratio 1.49.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Module power435 W is within the S440 rating of 440 W.
- ✓ Max input voltageVoc at the record low is 52.1 V, within the 60 V optimizer limit.
- ✓ MPPT windowVmp stays inside 8–60 V from the coldest to the hottest day.
- ✓ Module short-circuit currentIsc 11.57 A is within the 15 A limit.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 8–15 panels per string (best 13) |
| Chicago, IL | −21 °C | 8–15 panels per string (best 13) |
| Denver, CO | −23.6 °C | 8–15 panels per string (best 13) |
| Atlanta, GA | −9.5 °C | 8–15 panels per string (best 13) |
| Dallas, TX | −7.1 °C | 8–15 panels per string (best 13) |
| Phoenix, AZ | 1.3 °C | 8–15 panels per string (best 13) |
| Miami, FL | 5.9 °C | 8–15 panels per string (best 13) |
Common system sizes
How SunPower SPR-M435 panels lay out on the SolarEdge SE11400H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 14 | 1 string of 14 on 1 inverter | 6.09 kWp | 0.53 |
| About 8 kW | 18 | 2 strings of 9 on 1 inverter | 7.83 kWp | 0.69 |
| About 10 kW | 23 | 1 × 12 + 1 × 11 panels on 1 inverter | 10.01 kWp | 0.88 |