Home › Compatibility › SunPower SPR-MAX3-425-R + SolarEdge SE5000H-US

SunPower SPR-MAX3-425-R with SolarEdge SE5000H-US

Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.

✓

Compatible

Yes, with the SolarEdge S440 optimizer on every panel. Strings of 8–18 panels work (best 13), each delivering up to 5,700 W. One SolarEdge SE5000H-US takes up to 2 strings of 13: 18 panels, 7.65 kWp DC, DC/AC ratio 1.53.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C8–18 panels per string (best 13)
Chicago, IL−21 °C8–18 panels per string (best 13)
Denver, CO−23.6 °C8–18 panels per string (best 13)
Atlanta, GA−9.5 °C8–18 panels per string (best 13)
Dallas, TX−7.1 °C8–18 panels per string (best 13)
Phoenix, AZ1.3 °C8–18 panels per string (best 13)
Miami, FL5.9 °C8–18 panels per string (best 13)

Common system sizes

How SunPower SPR-MAX3-425-R panels lay out on the SolarEdge SE5000H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW141 string of 14 on 1 inverter5.95 kWp1.19
About 8 kW191 × 10 + 1 × 9 panels on 2 inverters8.07 kWp0.81
About 10 kW242 strings of 12 on 2 inverters10.20 kWp1.02