Home › Compatibility › Talesun BiPro TM7G54M-425 + SMA SBSE11.5-US-50

Talesun BiPro TM7G54M-425 with SMA SBSE11.5-US-50

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 3–14 panels work. The longest string reaches 583 V on the coldest morning, under the 600 V inverter limit. One SMA SBSE11.5-US-50 takes up to 4 strings of 13: 52 panels, 22.10 kWp DC, DC/AC ratio 1.92.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C3–13 panels per string (best 12)
Chicago, IL−21 °C3–14 panels per string (best 13)
Denver, CO−23.6 °C3–13 panels per string (best 12)
Atlanta, GA−9.5 °C3–14 panels per string (best 13)
Dallas, TX−7.1 °C3–14 panels per string (best 13)
Phoenix, AZ1.3 °C3–14 panels per string (best 13)
Miami, FL5.9 °C3–14 panels per string (best 14)

Common system sizes

How Talesun BiPro TM7G54M-425 panels lay out on the SMA SBSE11.5-US-50 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW141 string of 14 on 1 inverter5.95 kWp0.52
About 8 kW191 × 10 + 1 × 9 panels on 1 inverter8.07 kWp0.70
About 10 kW242 strings of 12 on 1 inverter10.20 kWp0.89