Home › Compatibility › Talesun BiPro TM7G72M-585 + Enphase IQ8HC-72-M-US

Talesun BiPro TM7G72M-585 with Enphase IQ8HC-72-M-US

Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.

!

Compatible, with a caution

Yes. Each IQ8HC-72-M-US takes 1 panel, and up to 10 units fit on one 20 A branch circuit (10 panels). DC/AC ratio 1.54. Check the MPPT window, cold day; Module power pairing below.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C1 panel per unit (check: MPPT window, cold day)
Chicago, IL−21 °C1 panel per unit (check: MPPT window, cold day)
Denver, CO−23.6 °C1 panel per unit (check: MPPT window, cold day)
Atlanta, GA−9.5 °C1 panel per unit (check: MPPT window, cold day)
Dallas, TX−7.1 °C1 panel per unit (check: MPPT window, cold day)
Phoenix, AZ1.3 °C1 panel per unit (check: MPPT window, cold day)
Miami, FL5.9 °C1 panel per unit (check: MPPT window, cold day)

Common system sizes

How Talesun BiPro TM7G72M-585 panels lay out on the Enphase IQ8HC-72-M-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW1010 × IQ8HC-72-M-US on 1 branch circuit5.85 kWp1.54
About 8 kW1414 × IQ8HC-72-M-US on 2 branch circuits8.19 kWp1.54
About 10 kW1717 × IQ8HC-72-M-US on 2 branch circuits9.95 kWp1.54