Tesla TSP-420 with Tesla Solar Inverter 7.6 kW
Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 3–13 panels work. The longest string reaches 581 V on the coldest morning, under the 600 V inverter limit. One Tesla Solar Inverter 7.6 kW takes up to 4 strings of 12: 48 panels, 20.16 kWp DC, DC/AC ratio 2.65.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning40.95 V × (1 + -0.261%/°C × (−10 − 25)) = 44.69 V per panel.
- Vmp on the hottest afternoonCells reach 68.5 °C (40 °C air plus the NMOT rise), so Vmp drops from 34.29 V to 28.47 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string600 V inverter limit ÷ 44.69 V = 13 panels.
- Shortest string60 V MPPT minimum ÷ 28.47 V = 3 panels.
- Strings per MPPTHot-day Isc 13.29 A per string, so the MPPT inputs take 1 + 1 + 1 + 1 string(s).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 3–12 panels per string (best 11) |
| Chicago, IL | −21 °C | 3–13 panels per string (best 11) |
| Denver, CO | −23.6 °C | 3–13 panels per string (best 11) |
| Atlanta, GA | −9.5 °C | 3–13 panels per string (best 12) |
| Dallas, TX | −7.1 °C | 3–13 panels per string (best 12) |
| Phoenix, AZ | 1.3 °C | 3–13 panels per string (best 12) |
| Miami, FL | 5.9 °C | 3–13 panels per string (best 13) |
Common system sizes
How Tesla TSP-420 panels lay out on the Tesla Solar Inverter 7.6 kW for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 14 | 2 strings of 7 on 1 inverter | 5.88 kWp | 0.77 |
| About 8 kW | 19 | 1 × 10 + 1 × 9 panels on 1 inverter | 7.98 kWp | 1.05 |
| About 10 kW | 24 | 2 strings of 12 on 1 inverter | 10.08 kWp | 1.33 |