Home › Compatibility › Trina Solar Vertex S+ TSM-440NEG9R.28 + APsystems DS3-S
Trina Solar Vertex S+ TSM-440NEG9R.28 with APsystems DS3-S
Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.
!
Compatible, with a caution
Yes. Each DS3-S takes 2 panels, and up to 6 units fit on one 20 A branch circuit (12 panels). DC/AC ratio 1.38. Check the MPPT window, cold day below.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Max input voltageVoc at the record low is 56.6 V, within the 60 V limit (94%).
- ✓ MPPT window, hot dayVmp on the hottest day is 37.4 V, inside 22–48 V.
- ! MPPT window, cold dayVmp rises to 49.1 V on cold days, above the 48 V MPPT maximum, so tracking is off-peak then.
- ✓ Input currentImp 10.02 A is within the 16 A max input current. The datasheet gives no separate Isc limit.
- ✓ Module power pairing440 W is inside the recommended 250–480 (DC/AC 1.38).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 2 panels per unit (check: MPPT window, cold day) |
| Chicago, IL | −21 °C | 2 panels per unit (check: MPPT window, cold day) |
| Denver, CO | −23.6 °C | 2 panels per unit (check: MPPT window, cold day) |
| Atlanta, GA | −9.5 °C | 2 panels per unit (check: MPPT window, cold day) |
| Dallas, TX | −7.1 °C | 2 panels per unit (check: MPPT window, cold day) |
| Phoenix, AZ | 1.3 °C | 2 panels per unit |
| Miami, FL | 5.9 °C | 2 panels per unit |
Common system sizes
How Trina Solar Vertex S+ TSM-440NEG9R.28 panels lay out on the APsystems DS3-S for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 14 | 7 × DS3-S on 2 branch circuits | 6.16 kWp | 1.38 |
| About 8 kW | 18 | 9 × DS3-S on 2 branch circuits | 7.92 kWp | 1.38 |
| About 10 kW | 23 | 12 × DS3-S on 2 branch circuits | 10.12 kWp | 1.32 |