Trina Solar Vertex S+ TSM-440NEG9R.28 with Fronius Symo 20.0-3 480

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 6–17 panels work. The longest string reaches 962 V on the coldest morning, under the 1000 V inverter limit. One Fronius Symo 20.0-3 480 takes up to 3 strings of 16: 48 panels, 21.12 kWp DC, DC/AC ratio 1.06.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C6–17 panels per string (best 15)
Chicago, IL−21 °C6–17 panels per string (best 15)
Denver, CO−23.6 °C6–17 panels per string (best 15)
Atlanta, GA−9.5 °C6–17 panels per string (best 16)
Dallas, TX−7.1 °C6–17 panels per string (best 16)
Phoenix, AZ1.3 °C6–18 panels per string (best 16)
Miami, FL5.9 °C6–18 panels per string (best 17)

Common system sizes

How Trina Solar Vertex S+ TSM-440NEG9R.28 panels lay out on the Fronius Symo 20.0-3 480 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded564 strings of 14 on 1 inverter24.64 kWp1.23
2 inverters, fully loaded1128 strings of 14 on 2 inverters49.28 kWp1.23
4 inverters, fully loaded22416 strings of 14 on 4 inverters98.56 kWp1.23