Home › Compatibility › Trina Solar Vertex S+ TSM-440NEG9R.28 + SMA SB5.0-1SP-US-41

Trina Solar Vertex S+ TSM-440NEG9R.28 with SMA SB5.0-1SP-US-41

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 3–10 panels work. The longest string reaches 566 V on the coldest morning, under the 600 V inverter limit. One SMA SB5.0-1SP-US-41 takes up to 1 string of 10: 10 panels, 4.40 kWp DC, DC/AC ratio 0.88.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C3–10 panels per string (best 10)
Chicago, IL−21 °C3–10 panels per string (best 10)
Denver, CO−23.6 °C3–10 panels per string (best 10)
Atlanta, GA−9.5 °C3–10 panels per string (best 10)
Dallas, TX−7.1 °C3–10 panels per string (best 10)
Phoenix, AZ1.3 °C3–10 panels per string (best 10)
Miami, FL5.9 °C3–10 panels per string (best 10)

Common system sizes

How Trina Solar Vertex S+ TSM-440NEG9R.28 panels lay out on the SMA SB5.0-1SP-US-41 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 1 inverter6.16 kWp1.23
About 8 kW182 strings of 9 on 1 inverter7.92 kWp1.58
About 10 kW232 × 8 + 1 × 7 panels on 2 inverters10.12 kWp1.01