Home › Compatibility › Trina Solar Vertex S+ TSM-440NEG9R.28 + SMA SBSE7.7-US-50

Trina Solar Vertex S+ TSM-440NEG9R.28 with SMA SBSE7.7-US-50

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–10 panels work. The longest string reaches 566 V on the coldest morning, under the 600 V inverter limit. One SMA SBSE7.7-US-50 takes up to 3 strings of 9: 27 panels, 11.88 kWp DC, DC/AC ratio 1.55.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2–10 panels per string (best 9)
Chicago, IL−21 °C2–10 panels per string (best 9)
Denver, CO−23.6 °C2–10 panels per string (best 9)
Atlanta, GA−9.5 °C2–10 panels per string (best 9)
Dallas, TX−7.1 °C2–10 panels per string (best 9)
Phoenix, AZ1.3 °C2–10 panels per string (best 10)
Miami, FL5.9 °C2–10 panels per string (best 10)

Common system sizes

How Trina Solar Vertex S+ TSM-440NEG9R.28 panels lay out on the SMA SBSE7.7-US-50 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 1 inverter6.16 kWp0.80
About 8 kW182 strings of 9 on 1 inverter7.92 kWp1.03
About 10 kW232 × 8 + 1 × 7 panels on 1 inverter10.12 kWp1.32