Solar production by month
kWh made by 1 kW of panels in an average Hawaii year. August is the best month (142 kWh) and February the weakest (114 kWh).
| Month | Peak sun hours a day | kWh per kW |
|---|---|---|
| January | 4.8 | 116 |
| February | 5.1 | 114 |
| March | 5.4 | 130 |
| April | 5.7 | 134 |
| May | 5.8 | 137 |
| June | 5.9 | 135 |
| July | 5.8 | 136 |
| August | 5.9 | 142 |
| September | 5.7 | 132 |
| October | 5.5 | 131 |
| November | 4.9 | 116 |
| December | 4.8 | 118 |
Solar output across Hawaii
Yearly kWh per kW at each NREL weather station. Class I stations have the most complete measured record; Class II are reliable but with more gaps filled.
| Location | kWh per kW a year | Peak sun hours | Data class |
|---|---|---|---|
| Kapalua | 1,624 | 5.8 | II |
| Molokai (AMOS) | 1,599 | 5.7 | II |
| Kahului Airport | 1,598 | 5.7 | I |
| Barbers Point NAS | 1,552 | 5.6 | II |
| Lanai | 1,541 | 5.5 | II |
| Honolulu Intl Airport | 1,537 | 5.5 | I |
| Lihue Airport | 1,490 | 5.3 | I |
| Kaneohe Bay MCAS | 1,454 | 5.2 | II |
| Hilo International Airport | 1,321 | 4.7 | I |
Panels for the average Hawaii home
The average home here used 495 kWh a month in 2024 (EIA), 5,940 kWh a year. At 1,541 kWh per kW, covering all of it takes about 3.9 kW, or 9 panels of 430 W, roughly 194 sq ft of panels. Run your own numbers with the solar panel calculator.
What "peak sun hours" means
One peak sun hour is 1,000 W of sunlight on a square metre for an hour, 1 kWh/m². A day with 5 peak sun hours delivers as much energy as 5 hours of full sun, spread over the whole day. Tilting panels toward the sun collects more than flat ground, which is why the roof figure is higher than the flat (GHI) figure.
States with similar sun
| State | Peak sun hours | kWh per kW a year |
|---|---|---|
| Nevada | 5.8 | 1,603 |
| California | 5.6 | 1,586 |
| Utah | 5.5 | 1,559 |
| Hawaii | 5.5 | 1,541 |
| Colorado | 5.4 | 1,531 |
| Wyoming | 5.1 | 1,491 |
| Oklahoma | 5.2 | 1,472 |
Method: NREL TMY3 typical-year weather data (1991–2005) for every Class I and II station, modelled with the PVWatts method in pvlib: 1 kW of panels facing south at 20°, 14% system losses, 96% inverter, DC/AC ratio 1.2. State figure = median station. Real systems vary with direction, shade and local weather. All states.